My station is still very experimental, and is growing continously. The current status:

Band TRX PA Preamp Cable Antenna
144 MHz:
IC275E
25W
GS31B
350 W
SSB SP-2
0,9 dB (meas.)

15 m ECOFLEX-10
datasheet: 0.74 dB
measured: 0.82 dB

2 x 11 Ele Flexayagi
H 2000 cables
Combiner UKW-Ber.
432 MHz:
IC475E
25W
GS35B
450 W
SSB SP-70
1,2 dB (meas.)
15 m ECOFLEX-10
datasheet: 1.34 dB
measured: 1.45 dB
2 x 23 Ele Flexayagi
H 2000 cables
Combiner UKW-Ber.
1296 MHz:
IC7400 + TVTR
30W (RA18H1213)
TH308
600 W
DF9IC ATF331
0,9 dB (meas.)
15 m ECOFLEX-15
datasheet: 1.71 dB
measured: 2.70 dB
4 x 35 Ele Tonna
H 2000 cables
Combiner Tonna
2320 MHz:

IC7400 + TVTR

Ericsson
75 W +-
DF9IC ATF331 15 m ECOFLEX-15
abt. 4 dB
1.2 m solid dish
Ring feed
3400 MHz: IC7400 + TVTR Toshiba 40W
DF9IC ATF551 15 m AIRCELL-7
PA + preamp at ant
1.2 m solid dish
Ring feed
5760 MHz: IC7400 + TVTR to be built
to be built 15 m AIRCELL-7
PA + preamp at ant
1.2 m solid dish
Ring feed
10368 MHz:
planned       (1.2 m solid dish)

Rotators are Yaesu / Kenpro G-1000 (AZ) and Emotator EV-700 (EL, gear broken). The mast consists of 3 sections of 200x200 mm V2A, 150x150 mm Al and 120x120 mm Al and is integrated in the upper floor of the house. All parts of the antenna system can be maintained from the roof by a single person. The small antenna below is for my WLAN point-to-point link.

Cables between antennas, combiners and preamps are H2000. The bands above 1 GHz have a separate RX cable (AIRCELL-7). There are several AIRCELL-7 spare cables; I also have DC power 26 V / 100 A and Ethernet on the mast for future projects.

Further improvements are planned:

I found out that the ECOFLEX-15 cables I have installed are widely out of specification, and show attenuation values on 1296 MHz which are not better than ECOFLEX-10. They were bought new! I cannot replace them easily as they are installed in a protective tube so it will need some time to improve the situation. Very bad!

Measured attenuation for installed 30 m AIRCELL-7, 30 m ECOFLEX-10 and 30 m ECOFLEX-15. All cables measured with Agilent HP8712C VNA as two 15 m sections looped through at the mast top.

This page has been edited last time: 2012-06-10