My station is still very experimental, and is growing continously. The current status:
Band | TRX | PA | Preamp | Cable | Antenna |
144 MHz:
|
IC275E 25W |
GS31B 350 W |
SSB SP-2 0,9 dB (meas.) |
15 m ECOFLEX-10 |
2 x 11 Ele Flexayagi H 2000 cables Combiner UKW-Ber. |
432 MHz:
|
IC475E 25W |
GS35B 450 W |
SSB SP-70 1,2 dB (meas.) |
15 m ECOFLEX-10 datasheet: 1.34 dB measured: 1.45 dB |
2 x 23 Ele Flexayagi H 2000 cables Combiner UKW-Ber. |
1296 MHz:
|
IC7400 + TVTR 30W (RA18H1213) |
TH308 600 W |
DF9IC ATF331 0,9 dB (meas.) |
15 m ECOFLEX-15 datasheet: 1.71 dB measured: 2.70 dB |
4 x 35 Ele Tonna H 2000 cables Combiner Tonna |
2320 MHz:
|
IC7400 + TVTR |
Ericsson 75 W +- |
DF9IC ATF331 | 15 m ECOFLEX-15 abt. 4 dB |
1.2 m solid dish Ring feed |
3400 MHz: | IC7400 + TVTR | Toshiba 40W |
DF9IC ATF551 | 15 m AIRCELL-7 PA + preamp at ant |
1.2 m solid dish Ring feed |
5760 MHz: | IC7400 + TVTR | to be built |
to be built | 15 m AIRCELL-7 PA + preamp at ant |
1.2 m solid dish Ring feed |
10368 MHz:
|
planned | (1.2 m solid dish) |
Rotators are Yaesu / Kenpro G-1000 (AZ) and Emotator EV-700 (EL, gear broken). The mast consists of 3 sections of 200x200 mm V2A, 150x150 mm Al and 120x120 mm Al and is integrated in the upper floor of the house. All parts of the antenna system can be maintained from the roof by a single person. The small antenna below is for my WLAN point-to-point link.
Cables between antennas, combiners
and preamps are H2000. The bands above 1 GHz have a separate RX cable (AIRCELL-7).
There are several AIRCELL-7
spare cables; I also have DC power 26 V / 100 A and Ethernet on the mast for
future projects.
Further improvements are planned:
I found out that the ECOFLEX-15 cables I have installed are widely out of specification, and show attenuation values on 1296 MHz which are not better than ECOFLEX-10. They were bought new! I cannot replace them easily as they are installed in a protective tube so it will need some time to improve the situation. Very bad!
Measured attenuation for installed 30 m AIRCELL-7, 30 m ECOFLEX-10 and 30 m ECOFLEX-15. All cables measured with Agilent HP8712C VNA as two 15 m sections looped through at the mast top.
This page has been edited last time: 2012-06-10